Price is VAT-inclusive
Woodpecker LX16 Plus is a 3-wavelength dental diode laser combining 450nm blue, 650nm PBM and 976nm infrared laser technology for versatile dental applications.
Original price was: £4,300.00.£3,999.00Current price is: £3,999.00.
Woodpecker LX16 Plus is a 3-wavelength dental diode laser combining 450nm blue, 650nm PBM and 976nm infrared laser technology for versatile dental applications.
The Woodpecker LX16 Plus Diode Dental Laser System is a multifunctional dental laser platform combining 450 nm blue laser, 650 nm low-level laser therapy (LLLT), and 976 nm infrared laser technology in one system.
The three-wavelength configuration expands the range of clinical applications, from precise soft-tissue cutting and coagulation to photobiomodulation, wound healing, periodontal and endodontic bacterial reduction, pain management and selected TMJ applications.
The LX16 Plus combines multiple laser technologies with a large touchscreen interface, wireless foot-pedal control, integrated cooling and advanced optical coupling to provide dentists with a versatile platform for modern laser-assisted dentistry.
The 450 nm blue semiconductor laser is designed primarily for soft-tissue procedures, including:
The high absorption of 450 nm blue laser energy by biological tissues enables efficient cutting at relatively low power levels.
The visible blue wavelength also provides clear visual control during procedures. The system supports non-contact cutting, and the fiber tip does not require activation before use according to the supplied product information.
The 650 nm laser is intended for Low-Level Laser Therapy (LLLT), also known as photobiomodulation (PBM).
It is designed for applications where laser light is used therapeutically rather than primarily for cutting.
Potential applications described for the LX16 Plus include:
The 976 nm infrared laser is designed for applications requiring deeper tissue penetration.
According to the supplied product information, applications include:
The combination of 450 nm, 650 nm and 976 nm wavelengths allows clinicians to select different laser characteristics according to the intended clinical application.

Woodpecker LX16 Plus Diode Dental Laser System-3 Wavelengths for More Clinical Possibilities
One of the distinguishing features of the LX16 Plus is its 450 nm blue laser.
The supplied product information indicates that proteins, hemoglobin and melanin have substantially higher absorption coefficients at 450 nm compared with several commonly used near-infrared wavelengths.
This high absorption can allow effective soft-tissue cutting at relatively low power settings, typically within the 0.5–2 W range, while helping to minimize thermal effects when appropriate clinical parameters and technique are used.
The blue wavelength is also visible, providing direct visual feedback during treatment.
The LX16 Plus incorporates high-frequency pulse control with a pulse frequency of up to 20,000 Hz.
High power combined with short pulse widths is designed to support fast and precise soft-tissue cutting while helping reduce excessive thermal accumulation and carbonization.
This can contribute to more controlled laser-assisted procedures and potentially improved postoperative recovery when the system is used according to the appropriate clinical protocol.

Woodpecker LX16 Plus Diode Dental Laser System- High Frequency Pulse Control
The LX16 Plus uses a detachable optical fiber design intended to improve optical transmission efficiency and simplify fiber handling.
The fiber construction incorporates:
This construction is designed to provide efficient light transmission, temperature resistance, biocompatibility and improved fiber durability.

Woodpecker LX16 Plus Diode Dental Laser System-Advanced optical coupling technology
The fiber system incorporates a three-layer protective structure consisting of:
The supplied information states that the system can be autoclaved for repeated use, supporting practical infection-control workflows.
Autoclavable metal fiber tips and an aluminum alloy handpiece sleeve further simplify sterilization between procedures.
The LX16 Plus provides two methods of controlling the laser:
This allows clinicians to select the control method that best suits the procedure and their preferred working position.
Wireless foot-pedal control also reduces the need for a physical cable between the operator and the main unit.
The system features a large colour touchscreen designed for quick parameter selection and straightforward operation.
The responsive touch interface provides access to laser settings and treatment controls from the main unit.

Woodpecker LX16 Plus Diode Dental Laser System- Large Colour Touchscreen
The LX16 Plus uses an advanced control system incorporating a PID closed-loop control algorithm.
This is designed to regulate laser output accurately and maintain stable power during operation.
The system also incorporates Japanese semiconductor technology and German optical components according to the supplied product information, supporting stable laser operation and long-term system performance.
An integrated cooling system regulates the operating temperature of the laser system.
Temperature management is designed to help maintain stable laser output while supporting the longevity of the internal components.

Woodpecker LX16 Plus Diode Dental Laser System-Integrated cooling system
The LX16 Plus is supplied with laser protective goggles designed for the three wavelengths.
Protective eyewear is intended for use by the dentist, dental assistant and patient as appropriate to the clinical procedure and laser safety protocol.
Laser procedures should always be performed by appropriately trained professionals following the manufacturer’s instructions and applicable laser-safety requirements.
The three-wavelength configuration makes the Woodpecker LX16 Plus suitable for a broad range of potential dental laser applications.
The 450 nm blue laser can be used for appropriate soft-tissue procedures including:
The 976 nm infrared wavelength is designed for selected periodontal applications, including bacterial reduction and deeper tissue treatment.
The 976 nm wavelength can also be used for selected endodontic laser procedures where deeper tissue penetration and bacterial reduction are required.
The 650 nm wavelength provides a dedicated LLLT/PBM mode for therapeutic applications such as supporting healing, tissue recovery and inflammation management.
The infrared wavelength can also be used for selected pain-management applications according to the appropriate clinical protocol.
The supplied product information identifies the 976 nm wavelength as suitable for selected temporomandibular joint (TMJ) therapeutic applications.
The Woodpecker LX16 Plus provides three different laser wavelengths in one dental laser platform.
Instead of relying on a single wavelength for multiple applications, clinicians can select:
Combined with wireless control, a touchscreen interface, reusable fiber components, integrated cooling and closed-loop power regulation, the LX16 Plus is designed as a versatile laser platform for modern dental practices.

Woodpecker LX16 Plus Diode Dental Laser System-Product Specifications
| Specification | Details |
|---|---|
| Product Name | Woodpecker LX16 Plus Diode Dental Laser System |
| Product Type | Diode Dental Laser System |
| Laser Type | Semiconductor laser |
| Wavelengths | 450 nm / 650 nm / 976 nm |
| 450 nm Application | Soft-tissue cutting, ablation, coagulation, incision and excision |
| 650 nm Application | LLLT / Photobiomodulation |
| 976 nm Application | Periodontal, endodontic, pain-management and selected TMJ applications |
| Maximum Pulse Frequency | Up to 20,000 Hz |
| Control | Handpiece button / wireless foot pedal |
| Display | Large colour touchscreen |
| Cooling | Integrated cooling system |
| Power Regulation | PID closed-loop control |
| Fiber | Detachable optical fiber |
| Fiber Tip | Autoclavable metal fiber tips |
| Protective Eyewear | Three-wavelength laser safety goggles |

Woodpecker LX16 Plus Diode Dental Laser System-Product Specifications-accessories
The Woodpecker LX16 Plus is a three-wavelength dental diode laser system combining 450 nm blue laser, 650 nm LLLT/PBM and 976 nm infrared laser technology.
The system uses 450 nm, 650 nm and 976 nm wavelengths.
The 450 nm wavelength is primarily intended for soft-tissue applications including cutting, ablation, incision, excision and coagulation.
The 650 nm wavelength is designed for Low-Level Laser Therapy (LLLT), also known as photobiomodulation.
The 976 nm infrared laser is intended for applications involving deeper tissue penetration, including selected periodontal and endodontic procedures, bacterial reduction, pain management and TMJ applications.
Yes. The 976 nm infrared wavelength is designed to support selected periodontal applications, including bacterial reduction.
Yes. The 976 nm wavelength is designed for selected endodontic applications, including bacterial reduction and deeper tissue treatment.
Yes. The dedicated 650 nm wavelength is designed for LLLT and photobiomodulation applications.
Yes. The system supports wireless foot-pedal control, as well as control through the handpiece button.
According to the supplied product information, the 450 nm blue laser fiber does not require activation before use.
The LX16 Plus supports a pulse frequency of up to 20,000 Hz.
Yes. An integrated cooling system is designed to regulate the laser operating temperature and support stable output.
The supplied specifications describe an autoclavable fiber system incorporating protective layers and autoclavable metal fiber tips for repeated clinical use.
The Woodpecker LX16 Plus is a professional dental laser system. The appropriate wavelength, power, pulse parameters, fiber configuration and clinical technique should be selected according to the intended indication, manufacturer’s instructions, clinician training and applicable laser-safety requirements.
More Dental Diode Laser Systems
Reviews