Price is VAT-Inclusive
AI-powered dental photogrammetry for precise All-on-4, All-on-6 and All-on-X implant alignment, compatible with existing intraoral scanners and 95%+ implant systems.
£1,300.00
AI-powered dental photogrammetry for precise All-on-4, All-on-6 and All-on-X implant alignment, compatible with existing intraoral scanners and 95%+ implant systems.
Dental Photogrammetry · AI-Powered Full-Arch Alignment
AI-powered full-arch implant alignment for All-on-X, All-on-4 & All-on-6 workflows — encoded scanbody
technology, gingival reference scanning, and AI-powered data matching in one open digital system.
UltraFitScan is an advanced dental photogrammetry and AI-powered implant alignment
system designed to improve the accuracy and efficiency of digital workflows for edentulous
full-arch implant cases. By combining encoded scanbody technology, gingival reference scanning and
AI-powered data matching, UltraFitScan helps capture precise implant positions for demanding All-on-X,
All-on-4, All-on-6 and full-arch implant restoration workflows.
With a specified data acquisition error of ≤0.01 mm, broad compatibility with more than
95% of implant systems, and compatibility with existing intraoral scanners, UltraFitScan
provides an open and flexible approach to full-arch implant alignment and digital implant
reconstruction.
Full-arch implant cases present a unique challenge for conventional intraoral scanning.
In an All-on-4, All-on-6 or All-on-X case, implants may be distributed across a large
edentulous arch with limited anatomical landmarks between implant positions. This can make conventional scan
stitching more challenging and potentially introduce inaccuracies into the digital implant model.
UltraFitScan is specifically designed to address this challenge.
The system combines encoded implant scanbodies and gingival reference caps with AI-powered
data matching to provide additional reference information during full-arch scanning.
The result is a dedicated workflow for accurate implant-position acquisition and full-arch digital alignment.

UltraFitScan is specified to capture high-precision scan data with an error of ≤0.01 mm,
helping reproduce the spatial position of implants within the digital workflow.
For All-on-4 and All-on-6 restorations, accurate implant position and angulation are
fundamental to designing a passive-fitting full-arch prosthesis.
UltraFitScan is designed to provide reliable digital implant-position data that can be transferred into the
subsequent CAD/CAM full-arch workflow.
≤0.01 mm specified data acquisition error
This makes UltraFitScan particularly relevant to clinicians and laboratories performing precision-focused full-arch implant rehabilitation.

The key advantage of UltraFitScan is its focus on implant alignment in edentulous full-arch cases.
Rather than relying exclusively on the limited anatomical reference points available on an edentulous ridge,
UltraFitScan introduces dedicated reference information through its scanbody and gingival scanning workflow.
The captured data is processed through the UltraFitScan software for AI-powered data matching through
free software, helping establish the relationship between implant positions and the surrounding oral
structures.
This creates a digital foundation for:
Watch the video for more details:
UltraFitScan can be incorporated into digital workflows where four strategically positioned implants support a
complete fixed arch restoration.
Accurate acquisition of implant position and angulation is particularly important when designing the final prosthesis.
For six-implant full-arch restorations, UltraFitScan provides a dedicated approach to capturing the multiple
implant positions distributed across the edentulous arch.
The open and flexible nature of the system makes UltraFitScan suitable for broader All-on-X digital
implant workflows, where the number and distribution of implants may vary according to the treatment
plan.
One of the strongest advantages of UltraFitScan is its open scanner compatibility.
The manufacturer states that the UltraFitScan scanning body can be used with any intraoral
scanner, allowing dental practices to integrate full-arch photogrammetry into their existing digital
setup rather than purchasing a dedicated proprietary scanner ecosystem.
This means your existing IOS can become part of a more advanced:
Intraoral scanning + photogrammetry + AI alignment workflow

UltraFitScan is designed for broad implant-system compatibility, with the manufacturer stating compatibility
with more than 95% of implant systems on the market.
This makes the system suitable for multi-brand clinical environments where dentists may work with different implant manufacturers across their patient base.
Compatible systems include implant platforms from manufacturers such as:
Conventional intraoral scanning can become more difficult when scanning a completely edentulous arch because
the scanner has fewer natural anatomical landmarks to use for stitching.
UltraFitScan addresses this limitation by incorporating:
Dedicated scanbodies provide identifiable reference information for implant-position acquisition.
The HS caps provide additional soft-tissue reference data around the implants.
The captured datasets are processed and matched using the UltraFitScan software.
The resulting digital data can be transferred into dental CAD software for full-arch prosthetic design.
UltraFitScan is designed to reduce the amount of intraoral scanning required.
Instead of relying solely on extensive scanning of an edentulous arch, the workflow focuses on capturing the markers and relevant reference areas.
This can help reduce scanning time while providing the information required for accurate implant-position reconstruction.
For high-volume All-on-4, All-on-6 and All-on-X workflows, reducing unnecessary scanning can translate into a more efficient digital workflow and shorter chairside acquisition time.
UltraFitScan components are manufactured from TC4 ELI titanium alloy, using integrated forming and high-precision machining.
The manufacturer specifies machining tolerances within 0.005 mm.
The system also incorporates:
These features are designed to support repeated clinical use and dimensional stability.

UltraFitScan is available in S, M and L sizes, allowing clinicians to select the appropriate configuration according to implant position and anatomical conditions.
Two primary kit configurations are available:
| Kit | Screw Diameter |
|---|---|
| UF-A | M1.4 / M1.6 |
| UF-B | M1.8 / M2.0 |
UltraFitScan is not designed to lock clinicians into a single scanner or CAD ecosystem.
Its open workflow allows clinicians to combine:
This flexibility makes it particularly attractive to dental practices and laboratories already invested in digital dentistry.
The matched data can subsequently be imported into dental CAD software for full-arch implant prosthesis design.

UltraFitScan can support digital workflows involving:

| Specification | UltraFitScan |
|---|---|
| System | Full-Arch Reconstruction Data Acquisition System |
| Primary application | Edentulous full-arch implant cases |
| Technology | Dental photogrammetry + AI data matching |
| Specified data acquisition error | ≤0.01 mm |
| Scanner compatibility | Any intraoral scanner |
| Implant compatibility | >95% of implant systems |
| Material | TC4 ELI titanium alloy |
| Machining tolerance | ≤0.005 mm |
| Available sizes | S / M / L |
| UF-A screw diameter | M1.4 / M1.6 |
| UF-B screw diameter | M1.8 / M2.0 |
| Workflow | IOS scan → gingival scan → AI matching → CAD |
| CAD workflow | Compatible with dental CAD software |
Contact Dentinova for pricing, availability, and a demonstration of the UltraFitScan dental photogrammetry system.
| Kit: | UF-A (M1.4/M1.6), UF-B (M1.8/M2.0) |
|---|
Dr Manish Dighade –
As a dentist focused on full-arch implant rehabilitation and immediate loading protocols, I’m always looking for technologies that improve accuracy while simplifying the workflow.
After using the UltraFitScan UF-A, I found it to be a practical solution for full-arch digital records.
What I liked:
✅ Stable and accurate full-arch scan body system.
✅ Open-system compatibility, making it easy to integrate with different implant workflows.
✅ Simplified digital impression process, reducing chairside time.
✅ Well-designed kit with multiple scan bodies and accessories.
✅ Helpful for achieving passive-fit prostheses in full-mouth implant cases.
For clinicians transitioning from conventional impressions to a digital workflow, this system can significantly improve efficiency. A precise digital record ultimately contributes to better prosthetic outcomes and a smoother laboratory workflow.
Every digital system has a learning curve, but my initial experience with the UltraFitScan UF-A has been positive, and I look forward to incorporating it into more full-arch implant cases.
This review reflects my personal clinical experience and is not a sponsored endorsement.